Process temperature: -40 °C ... 80 °C (-40 °F ... 176 °F)
Process pressure absolute / max. overpressure limit: 0.7 bar ... 4 bar abs (10 psi ... 58 psi)
Max. measurement distance: 5 m (16ft)
Accuracy: +/- 2mm + 0.17% of measured distance
Main wetted parts: PVDF (fully welded IP68 / NEMA 6P)
Approval: Non-hazardous area
Process Connection: Thread ISO228 G1, PVDF
Cable Length: 10m/32ft
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Endress+Hauser FDU91-RG2AA Ultrasonic measurement Time-of-Flight Prosonic

Endress+Hauser FDU91-RG2AA Ultrasonic measurement Time-of-Flight Prosonic


Description:


Ultrasonic sensor for level and flow measurement for connection to FMU9x (measuring range?up to 10m)

Product name : Prosonic S FDU91

Extended order code : FDU91-RG2AA

R-Approval : Non-hazardous area

G-Process Connection : Thread ISO228 G1, PVDF

2-Cable Length:10m/32ft

A-Heater:W/o

A- Additional Option : Basic version

Shipping Weight : 2 Kg


Additional Informaiton:


The FDU91 ultrasonic sensor for continuous, non-contact and maintenance-free level measurement of fluids, pastes, sludges and powdery to coarse bulk materials. But also for flow measurement in open channels and measuring weirs. The measurement is unaffected by dielectric constant, density or humidity and also unaffected by build-up due to the self-cleaning effect of sensors. Suited for explosion hazardous areas. Maximum measuring range in liquids 10m (33ft), solids 5m (16ft).


Benefits


Integrated temperature sensor for Time-of-Flight correction. Accurate measurements are possible, even if temperature changes are present

Hermetically welded PVDF sensor for highest chemical resistance

Suited for rough ambient conditions thanks to separate installation from the transmitter
(up to 300m)

Reduced build-up formation because of the self-cleaning effect

Integrated automatic sensor detection for transmitters FMU90/FMU95 for simple commissioning

Weather resistant and flood-proof (IP 68)

Integrated heating against a build-up of ice at the sensor (optional) ensures reliable measurement

Show less


Field of application


Sensor for continuous, non-contact level measurement of fluids and of bulk materials in silos, on belts, stockpiles and in crushers. Also for flow measurement in open channels and at weirs. Typically used in measurements in low structural heights.

Process connection: Thread

Temperature: -40 to +80°C (-40 to +176°F)

Pressure: +0.7 to +4bar (+10 to +58psi)

Maximum measuring range: Liquids 10m (33ft), solids 5m (16ft)

Blocking distance: 0.3m (1ft)

International explosion protection certificates

Show less

Features and specifications


Continuous / Solids
Continuous / Liquids
Liquids
Measuring principle
Ultrasonic

Characteristic / Application
Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300m in-between sensor and transmitter

Supply / Communication
4-wire (HART , Profibus DP)

Accuracy
+/- 2mm + 0.17% of measured distance

Ambient temperature
-40 °C ... 80 °C
(-40 °F ... 176 °F)

Process temperature
-40 °C ... 80 °C
(-40 °F ... 176 °F)

Process pressure absolute / max. overpressure limit
0.7 bar ... 4 bar abs
(10 psi ... 58 psi)

Main wetted parts
PVDF (fully welded IP68 / NEMA 6P)

Process connection
G / NPT 1"

Blocking distance
0.3 m (1 ft)

Max. measurement distance
5 m (16ft)

Communication
Transmitter:
4 ... 20 mA HART
Profibus DP

Certificates / Approvals
ATEX, FM, CSA, IEC Ex, JPN Ex, INMETRO, NEPSI, EAC Ex


Options


Second 4...20mA output

Components
Transmitter:FMU90


Common Models:


CLM223-CD0005CPS11D-7BT21
CLM253-CD0005CKY10-A101
COM223-DX0005CPM253-MR0105
COM253-WX0005CPA250-A00
COM253-DX0005CPS11-2BT2ESA
CPM223-MR0005CPF81D-7LH11
CPM253-MR0005FTL31-AA4U3BAWSJ
CPM223-PR0005CLS15
CPM253-PR0005CLS21
COS41-2FCUS31
COS41-4FCOS41
COS61-A1F0CPS11D-7BA21
COS61-A2F0CCM253-EK0005
COS61D-AAA1A3CUM223/253
CPS11D-7AA21CLM223/253
CPS11D-7BA2GCPS41-1AC2SSA
CPS11D-7BA41CLS21-C1E4A
FTM51-AGG2M4A32AHCLS21-C1N2A
FTM51-AGG2M4A32AH L=500mmCLS21-C1N3A
CPS11D-7AS21CLS15-B1M2A
CPS11D-7BT2GCLS15-A1M2A
CPS12D-7NA21CLS15-A3D1A
CPS12D-7PA21CLS16
CPS11-2BA2ESACLS50
CPS71D-7TB21CLS54
CUS51D-AAD1A3CPS11
CUS52D-AA1AA3CPS71
CUS71D-AA1ACPS12
CYK10-A031CPS91
CYK10-A051CPS441
CYK10-A101CPS491
CYK10-A151CPS16
FDU91-RG1AACPS76
FDU91-RG2AACPS96
FDU91-RG3AACPS42
FDU92-RG2ACPS72
FMU30-AAHEAAGGFCPS92
FMU30-AAHEABGHFFTL20H-0TDJ2B
FMU40-ARB2A2FTL20H-0TCJ2BXI
FMU41-ARB2A2FTL20
Quality Endress+Hauser FDU91-RG2AA Ultrasonic measurement Time-of-Flight Prosonic for sale
Send your message to this supplier
 
*From:
*To: GREAT SYSTEM INDUSTRY CO. LTD
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0