4.75 5 5.25V 2us Response 900A DC Current Transducer

Categories Current Transducers
MOQ: 100
Payment Terms: T/T
Delivery Time: 1-12 weeks
Packaging Details: Original packing
Maximum range: 700A~900A
voltage: 4.75 5 5.25
Load Resistance: 10
Load capacitance: 5
Output internal resistance: 4
Electrical zero offset: ±4
Magnetic zero offset: ±3
Zero output error: ±0.5
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

4.75 5 5.25V 2us Response 900A DC Current Transducer

NACA.XXXQ1-S6 / VA Current Transducers


Product Details

product manual


NACA XXXQ1-S6/VA series current sensors are suitable for accurate measurement of AC, DC, and pulse current isolation. The primary side and the secondary side are completely insulated during measurement.

Performance requirements
parameter namesymbolunitparametercondition
MinimumTypical valueMax
Electrical parameters
Maximum rangeIPA700A~900AFor more details, please contact CRRC
voltageUCV4.7555.25
Operating temperatureTA°C-40125
Output voltage (analog)VoutVVout=(Uc/5)·(V0+G·Ip)
SensitivityGmV/AG=2000/IP@UC=5V
Zero outputVOV2.5
Current consumptionICmA3945@ UC=5V,No load on Vout
Load ResistanceRL4.710
Load capacitanceCLnF5
Output internal resistanceROUTΩ248DC
Performance parameter
Sensitivity errorεG%±1@TA=25℃,@UC=5V
±2@-40℃<TA<125℃,@UC=5V
Electrical zero offsetFLYmV±4
Magnetic zero offsetFROMmV±3
Zero output errorX0%±0.5@TA=25℃,@UC=5V
±0.75@-40℃<TA<125℃,@UC=5V
Proportional errorεR%±0.5
Linearity errorεL%±0.5of full range
Response timetrμs2
bandwidthBWkHz40@ -3dB
Phase difference∆φ°-4@DC to 1kHz

Dimensions
Series size

Mechanical parametersRemarks
● Plastic case PA66 -GF 30
● Magnetic core FeSi wound core
● Mass 88g
● VOUT>VO when IP flows in the positive direction (see arrow on drawing)