UKCA 30mA-300mA Residual Current Circuit Breaker RCCB Type EV 10kA
![]() |
Residual Current Circuit Breaker RCCB type EV 10kA Ultimate Short-Circuit Breaking Capacity VKL11F Residual Current Operated Circuit Breaker Type F EV 1.General 1.1Function Residual Current Circuit Breaker VKL11F TYPE F EV (RCCB TYPE F EV) is the Type EV RCCB which has been developed specifically for EV charging systems and can detect AC and DC residual currents......
Yueqing Vorax Electric CO.,LTD
|
Kampa Best Selling 4P 40A F7 Residual Current Circuit Breaker RCCB
![]() |
...Residual Current Circuit Breaker RCCB 1. High Quality. 2. W CE certificate 3. Very Comparative price 4. 4P Kampa Best Selling 4P 40A F7 Residual Current Circuit Breaker RCCB 1.Main technical specifications Number of poles 4P Breaking capacity 6KA Rated current(A) 25,40,63A Rated voltage(V) AC 2p 230V Rated residual operating current(mA) 30,100,300,500mA Rated residual non-operation current......
Yueqing Kampa Electric Co., Ltd.
|
4 Pole B model RCCB Residual Current Circuit Breaker RCCB , 6KA Smart Circuit Breaker
![]() |
...currents that may result from rectifying circuits and high frequency AC residual currents. It protects in the event of contunuous fault current on three phase networks.It usually is used in the field of Recharging Station,Medical Apparatus and Instruments,...
WENZHOU SANTUO ELECTRICAL CO.,LTD.
|
100mA / 300mA Residual Current Circuit Breaker RCCB IEC61008-1 Standard
![]() |
... of230V(1P+N) or 400V(3P+N),and rated current of 100A.In case of electric shock or electric leakage current exceeds the specified value, the residual current circuit breaker can switch off the fault circuit in a very short time, protecting the safety of...
Wenzhou New Blue Sky Electrical Co.,Ltd
|
240V Residual Current Circuit Breaker RCCB / 2 Pole Circuit Breaker IP20
![]() |
...residual current circuit breaker RCCB Rated resudual operating current In(A):0.03,0.1,0.3,0.5 Rated conditional short-circuit current Inc:10kA Terminal Connection Height:21mm Electro-machanical endurance:4000 cycles Connection capacity:Rigid conductor 25mm2 Connection terminal:Screw terminal type In/A I△n/A Residual Current......
Zhejiang Sefie Electric Co.,Ltd.
|
Residual Current Circuit Breaker RCCB
![]() |
Residual Current Circuit Breaker Mini RCCB Application UKF7 series Residual Current Circuit Breaker provide the function of isolation switching and earth leakage protection of electrical circuits. And also provide the indirect protection of the operator's body against the dangerous effects of electric current and provide the protection of the fire caused by the electrical circuit......
Zhejiang KRIPAL Electric Co., Ltd.
|
Electromagnetic Type Residual Current Circuit Breaker 4 Pole 63A 30ma RCCB
![]() |
...Residual Current Circuit Breaker 4 Pole 63A 30ma RCCB Application: F360 series residual current circuit breakers (RCCB) are in accordance with the standards of IEC1008-1 and GB16916.1-1997. They are applied to the circuit of AC 50/60Hz, 2P 240V, 4P 415V. They are mainly used for preventing electric fire and personal casual accidents caused by personal electric shock or leakage. They are current......
YueQing ZEYI Electrical Co., Ltd.
|
B Type 400V RCCB Residual Current Circuit Breaker ELCB 63 Amp 4 Pole 30ma
![]() |
... currents, thus ensuring protection against electric shocks caused by indirect contact. These devices must be used in series with MCBs or fuses to protect them from the potentially damaging ......
Chengdu Honors Technology Co.,Ltd
|
Model ID 63A RCCB Residual Current Circuit Breaker 30mA 2P 4P
![]() |
...A and S 50/60Hz, voltage 240V(2pole)/415V(4pole), rated current up to 63A.When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, it will cut off the power rapidly to protect human safety and prevent the...
Wuxi Fenigal Science & Technology Co., Ltd.
|
RCCB 4 Pole Residual Current Circuit Breakers 40A 63A 230V 400V 0.03mA
![]() |
RCD Type B 2P 4Pole 40A 63A 230V 400V 0.03mA Residual Current Circuit Breaker Product Description: Type B RCDs. Protection against shock and fire hazards during EV charging. Requires detection of AC and DC residual fault currents. This can be achieved by ......
Chengdu Heiu Technology Co., Ltd.
|